Remote Set-Up
AX3000 - User's Manual 191
When the set-up parameters have been loaded, the message '
OK, set-up
sent
' is displayed on the operator’s console. If other messages are displayed,
refer to chapter 10.2.3.
The configuration file lists each set-up parameter. Refer to Appendix A.5 for a
detailed description of this file.
10.2.3 - Error Messages
There are two types of error:
- fatal errors: numbered from 100 to 114,
- warning errors: numbered from 200 to 221.
a) Fatal Errors
Fatal errors stop the remote command. The following fatal errors may occur:
ERR 101: header label expected.
Command: setup_send
Cause: the AXEL header label (BEGIN_AX_SETUP) is not the first
line of the configuration file.
Consequence: the AX3000 set-up is not modified.
Solution: check the file. Replace it with a correct configuration file.
ERR 102: bad header label protocol version.
Command: setup_send
Cause: the protocol version (included in the header label) cannot be
processed by the current AX3000 firmware.
Consequence: the AX3000 set-up is not modified.
Solution: use a configuration file with a compatible protocol.